We introduce the IPS System of Supportec Co., Ltd.

Safety of IPS System

Structural Analysis

Based on a structural analysis of 32m long IPS wale, the max, moment and the max, Shear force depend on the distance between support beams, and they are decreased by 95%, which is almost no moment and no shear are found in the IPS system. The IPS wale should be a double wale for supporting 488ton. The max, displacement in center is 2.3mm.

Safety Analysis

The safety of IPS system has been analyzed for abnormal cases such as excessive high earth pressure, uneven earth pressure of PC tendon failure. Most of the cases are turned out to be safe except for one case, when both the earth pressure and the tension of PC tendon increases by 30%.

Safety verification by measuring FD

Standard table of FD Detection

(Unit: mm)

NO. Accumulate Displacement Countermeasure Excavation Criteria Note
Excavation Depth
1 15 ~ 30 10 H / 500 Safe
2 30 ~ 50 30 H / 300 Attention
3 50 ~ 50 H / 200 Danger
Measuring Point Anchor and Center of IPS wale
Measurement Method Laser distance measuring device
Principle Measured deflection of IPS wale predicts the forces of soil pressure, Wale and strut forces and tendon tension.

Deformation and stiffness of IPS stripe according to ground load change

Ensuring the safety of IPS based on the destruction progress

- The strut is designed to be stronger than the IPS wrist strap.
- The initial tension of the belt is 70% of the design load.
- If the earth pressure exceeds 70% of the design load, the band zone begins to deform toward the excavation field.
- Step pressure and corresponding method are shown in the table below.

Soil Pressure
(% of Design Value)
Countermeasure Deformation(mm) Stage Measuring(times/week)
1st step 70% - Increase prestressing force from 70% to 100% Under 10mm safe 1
2nd step 70% - Increase prestressing force up to 100% of design value to meet excessive soil pressure 10~30 attention 2
3rd step 100% - Wale or Strut Reinforcement
- Increase prestressing force of tendon
30~50 alert 3
4th step 130% - Install additional tendon
- Install interlayer strut and wale
Above 50mm danger everyday

Grooving: Transferring lateral loads to the wall

※ Resistance to lateral forces F0 = Fwale + Fweld

※ The sum of the lateral resistance of the CIP(Fwall) and Skin Friction(Fsoil) of CIP and Soil is equal to the shear force generated in the grooved weld(Fweld).

Welding TYPE Permissible welding steel (ton/ea)
Weight 6mm 10mm
A 84 ton 141 ton
B 56 ton 94 ton
C 28 ton 47 ton